简介:Thisworkinvestigatesinternalplasmaprocessparametersusingahairpinresonanceprobeandopticalemissionspectroscopy.ThedependenceofelectrondensityandatomicfluorineonthepercentageofoxygeninanSF6/O2dischargewasmeasuredusingthesemethods.AnRIEOxfordInstruments80pluschamberwasusedfortheexperiments.Twodifferentprocesspowers(100Wand300W)ataconstantpressure(100mTorr)wereused,anditwasfoundthattheopticalemissionintensityofthe703.7nmand685.6nmlinesofatomicfluorineincreasedrapidlyasoxygenwasaddedtotheSF6discharge,reachedtheirmaximumatanO2fractionof20%andthendecreasedwithfurtheradditionofoxygen.TheplasmaelectrondensitywasalsostronglyinfluencedbytheadditionofO2.
简介:Anewtwo-dimensionalstructuremodulationalongc-andb-axeshasbeendiscoveredinsuperconductingsinglecrystalsofBi2.13Sr1.87CuO6+δ(Bi2201)byx-rayscattering.Suchmodulationstructuredoesnotexistinnon-superconductingBi2201singlecrystals.Butinsteadlatticedistortionsareobservedinthea-b-plane.Thisphenomenonmayindicatethatbothstrainrelaxationandchargemodulationinthea-b-planeareimportanttotheoccurrenceofsuperconductivityinthecopperoxides.
简介:压力管卧式重水反应堆(CANDU6)具有相互独立的冷却剂系统和慢化剂系统。慢化剂系统将堆芯高能裂变中子慢化到能维持持续裂变所需的热中子水平,并将慢化中子过程中产生的热量带出。在反应堆大修期间,需要对再循环冷却水系统(RCW)进行检修,则需要并投入其备用系统,但是RCW备用系统仅对反应堆冷却剂系统进行冷却,不提供慢化剂系统热交换器冷却水。所以在RCW备用系统投入的情况下,慢化剂系统丧失冷却。为判断在此情况下慢化剂的温度变化情况,本文对CANDU6大修期间慢化剂系统丧失冷却情况下的温度变化进行分析并与试验结果进行比较,评估是否会由于温度过高而导致系统失效。
简介:
简介:国家核安全局于1995年发布了《核设备抗震鉴定试验指南》(HAF·J0053),对我国核设备抗震鉴定工作起到了很好的指导作用.《指南》的“多频波法”要求“由每个人工加速度时程计算出的在频率0.3Hz至24Hz范围内的功率谱密度(PSD)曲线必须包络由要求反应谱计算出的对应频率范围的功率谱密度80%的曲线”.但如何根据“要求反应谱”推导出具有合理保守性的可接受的“功率谱密度”是至今尚未解决的问题,这给核安全监管工作带来很大困惑.本文首先从编制《指南》的主要参考蓝本入手,分析了功率谱密度要求的意义及必要性;然后从反应谱和功率谱密度的定义和计算方法着手,结合“合理保守性”的监管原则,探讨从“要求反应谱”推导“最低可接受功率谱密度”的方法;最后,对我国今后相关的规范标准制定和修订工作以及核安全监管工作提出建议.